Mark Air Particulate Control Systems
Mark Air Particulate Control Systems
Ashok Nagar, Chennai, Tamil Nadu
Send SMS
Send E-mail

Calibration & AMC Services

We have successfully achieved a strong foothold over the domestic market offering world-class service in respect of monitor calibration services & AMC services that includes Service/Validation. We check HEPA filter integrity test as per IES recommendation, on the basis of periodic checking of airflow velocity, uniformity, static pressure etc and undertake service for any make of Laminar Airflow/HEPA filtration equipment. We are looking for inqueries from South India & Overseas Countries.
Request CallBack
Validation Services
Get Best Quote

Validation Services

Approx. Price: Rs 5,000 / Day
Product Details:
Validation TypeLeak Test
Certification TypePressure Balancing Certification
Cleanroom TypeAny
Prevention ParticleMicrobes
Number of Rooms>3
Instrument ValidationLaminar Air Flow Validation
Application/UsageR & D
Room Size300 to 500 Square Feet
Our credible services and validation has helped us in garnering multiple clients over the years. We stringently undertake HEPA tests for airflow velocity, uniformity, static pressure etc as per the standard norms. The HEPA filter integrity test is carried out as per IES recommendation, using an Imported Digital Photometer, which is, state-of-the-art and tamper proof. In fact, we offer our service for any make of Laminar Airflow/HEPA filtration equipment. The data gathered from these tests serve as baseline information to determine the current operational status and as justification for repairs or modification. Our credible services and validation has helped us in garnering multiple clients over the years. We stringently undertake HEPA tests for airflow velocity, uniformity, static pressure etc as per the standard norms. The HEPA filter integrity test is carried out as per IES recommendation, using an Imported Digital Photometer, which is, state-of-the-art and tamper proof. In fact, we offer our service for any make of Laminar Airflow/HEPA filtration equipment. The data gathered from these tests serve as baseline information to determine the current operational status and as justification for repairs or modification.

HEPA Filter Integrity Test Procedure
IES Recommendation (IES-RP-CC-002-86) :

• Di-Octyl-Phthalate (DOP) or equivalent Aerosol is introduced in the upstream HEPA filter, so as to produce uniform challenge concentration

• This concentration is set at 100% or full scale

• With this as reference, downstream HEPA filter face is scanned with Photometer Probe for Possible leaks

• All tests and checks are reported in a Scientific and easy-to-follow manner

• Our Test reports are comprehensive with all required details to satisfy any regulatory authority

• We can supply HEPA filters (both Minipleat and Separator Type) and Pre-filters of any size and any rating, for replacement requirements

• Minipleat filters are state-of-the-art machine made filters without aluminum separators to ensure superior performance and longer life.

The following tests will be carried-out as part of Validation of Clean Rooms/ Laminar Flow Units:


• HEPA filter integrity test using Photometer and Challenge Aerosol
• Particle count in each of the clean rooms as per US Federal Standards 209E.
• Checking and Setting Pressure gradient inside the rooms
• Air velocity and volume flow through HEPA filters
• Temperature & Humidity inside the Rooms
• Reporting all the above tests, with test procedure reference The test instruments used for the above test are calibrated to National Standards, such as NABL.

For Clean Rooms:


• We undertake validation on Call basis or periodically for a specified period
• Scope of work will be as mutually agreed and as mentioned in our offer.
• Our rates for One-time Service, AMC and Clean Room Validation jobs are most competitive, when compared with others offering the same service.
• We undertake general service, modification and up gradation of existing Clean Rooms.

Yes! I am Interested
Request CallBack
HEPA Filter Testing
Get Best Quote

HEPA Filter Testing

Approx. Price: Rs 5,000 / Day(s)
Professional Calibration Team with all Test Instuments.

Calibration of Clean Room HEPA filtration Systems particularly Laminar Flow Units, Biological Safety Cabinets, Clean Room HEPA filters is essential and has to be repeated atleast once a year.

The following Tests have to be carried out for Compliance to various Regulators / Standards:
(We undertake all of these and we own all these instruments. All instruments are Calibtrated with Traceability to NABL or National Standards)

All tests or selective tests can be carried out:
  1. HEPA filter Integrity Test (PAO/DOP Test) as per IES-RP-CC
  2. Room Particle Count Test with compliance to ISO or US Fed Standard
  3. Air Velocity measurement
  4. UV intensity
  5. Pressure pressure Drop
  6. Room Positive Pressure
  7. Clean Room Air Changes and AHU capacity calculation/confirmation
  8. Airflow Visualisation
  9. Light intensity test using Lux meter
  10. Noise level test
We do professional work and our charges are also economical.

NABL accredited Calibrators / Labs shall also contact us.

Scientific Instrument suppliers or agents shall also contact us.

We also undertake monthly / periodic testing service for Pharma mfrs, Hospitals, Labs and Institutions on Annual or per call basis.

Yes! I am Interested
Request CallBack
Particle Count Test for Clean Rooms
Get Best Quote

Particle Count Test for Clean Rooms

Approx. Price: Rs 5,000 / Day(s) Onwards
CLEAN ROOM PARTICLE COUNT

Professional Calibration Team with all Test Instuments.

Calibration of Clean Room HEPA filtration Systems particularly Laminar Flow Units, Biological Safety Cabinets, Clean Room HEPA filters is essential and has to be repeated atleast once a year.

The following Tests have to be carried out for Compliance to various Regulators / Standards:
(We undertake all of these and we own all these instruments. All instruments are Calibtrated with Traceability to NABL or National Standards)

All tests or selective tests can be carried out:
  1. HEPA filter Integrity Test (PAO/DOP Test) as per IES-RP-CC
  2. Room Particle Count Test with compliance to ISO or US Fed Standard
  3. Air Velocity measurement
  4. UV intensity
  5. Pressure pressure Drop
  6. Room Positive Pressure
  7. Clean Room Air Changes and AHU capacity calculation/confirmation
  8. Airflow Visualisation
  9. Light intensity test using Lux meter
  10. Noise level test
We do professional work and our charges are also economical.

NABL accredited Calibrators / Labs shall also contact us.

Scientific Instrument suppliers or agents shall also contact us.

We also undertake monthly / periodic testing service for Pharma mfrs, Hospitals, Labs and Institutions on Annual or per call basis.

Yes! I am Interested
Save time! Get a Best Deal

*Your information is safe with us.

Request CallBack

Laminar Flow Calibration

Approx. Price: Rs 5,000 / Piece
Calibration of Laminar Flow Units and all HEPA filtration systems traceable to NABL. Already having more than 500 units/filters under contract all over India.

  • HEPA filter Integrity (DOP/PAO Test
  • Particle Count Test
  • Air Velocity etc.

Additional Information:
  • Minimum Order Quantity: 1 Piece
Get Best Quote
Yes! I am Interested

Explore more products

X
Looking for “Calibration & AMC Services”?